MAYSATHAISEMASSAGE.NL ≡ Nephrology D & Dd Cup Mbbs Medical Education
  • Power Distribution Unit (Pdu)

  • APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P N PE cord PDU

APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P N PE cord PDU

$38.93 $57.62
Specifications Product datasheet Specifications APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P N PE cord AP8886 Overview Presentation APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower the total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/ humidity sensor port, locking IEC receptacles, and ultra-low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency. Lead time Usually in Stock Main Main Input Voltage 400 V 3 phases PDU type Metered Main Output Voltage 230 V Input Connection Type IEC 60309 32 A 3P N E Number of rack unit 0U Cable length 1.83 m Provided equipment Installation guide Rack mounting brackets Serial configuration cable Safety guide Physical Colour Black Height 182.9 cm Width 5.6 cm Depth 5.1 cm Product weight 8.72 kg Mounting location Side Mounting preference No preference Mounting mode Rack-mounted Mounting position                                      Vertical 27 Jul, 2023    1 Input Max line current      32 A Input current limits 32 A Load capacity 22000 VA Network frequency                                   50/60 Hz Output Number of power socket outlets      30 IEC 60320 C13 12 IEC 60320 C19 Conformance Product certifications VCCI class A VDE Standards      EN 55022 class A      EN 55024      EN 61000-3-2      EN 61000-3-3      FCC part 15 class A      ICES-003 Environmental Ambient air temperature for operation      -5…60 °C Relative humidity      5…95 % Operating altitude      0…10000 ft Ambient air temperature for storage      -25…65 °C Storage Relative Humidity      5…95 % Storage altitude                                          0.00…15240.00 m Packing Units Unit Type of Package 1      PCE Number of Units in Package 1      1 Package 1 Height      205 cm Package 1 Width      11.2 cm Package 1 Length      17 cm Package 1 Weight                                       11.55 kg Offer Sustainability Sustainable offer status      Green Premium product REACh Regulation      REACh Declaration EU RoHS Directive     Compliant EU RoHS Declaration Lead free      Yes Mercury free      Yes RoHS exemption information      Yes Environmental Disclosure      Product Environmental Profile Circularity Profile                                       End of Life Information       2    27 Jul, 2023 WEEE      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins Optimized Energy Efficiency      Energy efficient product Take-back Contractual warranty      Take-back program available Warranty                                                          2 years repair or replace Recommended replacement(s) 27 Jul, 2023
Power Distribution Unit (Pdu)

Power Distribution Unit (Pdu)

  • APC NetShelter Metered Rack PDU, 2U, 1PH, 7.4kW 230V 32A, x12 C13 and x4 C19 outlets, IEC 309 cord PDU
    $47.39 $58.29
  • APC NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 Outlets, C20 Cord PDU
    $64.45 $79.92
  • APC NetShelter Switched Rack PDU, 1U, 1PH, 2.3kW 230V 10A or 2.5kW 208V 12A, 8 C13 Outlets, C14 cord PDU
    $43.22 $72.18
  • APC NetShelter Metered-by-Outlet Rack PDU, 0U, 1PH, 7.4kW 230V 32A, x21 C13 and x3 C19 Outlets, IEC 309 Cord PDU
    $40.11 $69.39
  • APC Rack PDU 2G, Metered by Outlet with Switching, Zero U, 32A, 230V, (21) C13 & (3) C19 PDU
    $61.85 $74.84
  • APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P N PE cord PDU
    $38.93 $57.62
  • APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19 PDU
    $43.43 $77.74

© 2026 - MAYSATHAISEMASSAGE.NL